R e a r P a n e l F e a t u r e s
Inputs
Each channel of the PZS
level inputs. These inputs are terminated to removable Euro connectors
for balanced connections to external audio circuits. For information on
how to terminate a Euro connector, please see page 15.
Channels 1 and 2 are "priority" inputs and include special functionality
that allow them to be used as vox-based paging priority channels. This
functionality is controlled from the front panel TRIGGER and HOLD
controls. (See page 10.)
In addition to the line and mic-level inputs, channels 3, 4 and 5 include
dual female RCA connectors that include an internal summing network.
These inputs should be used with stereo (two-channel) line-level
sources with a nominal output level of -10 dBm.
Digital Remote Control
The PZS 140RA supports the Peavey Architectural Acoustics D-Series
D4S remote control panel. The D4S connects directly to the PZS 140RA
via the rear panel DIGITAL REMOTE CONTROL connector. This connector
is a female RJ-45 jack designed to connect the controllers using
standard Category 5 (CAT5) cable.
For more information on the DIGITAL REMOTE CONTROL feature, please
see page 19.
Phantom Power
Pressing the 48 Volt Sub-panel switch activates the 48 Volt Phantom
Power on Mic inputs 1 through 5.
P A G E 1 2
™
140RA includes line-level and microphone-
P Z S
™
-140RA User Manual
Each channel can receive only one
type of audio input at a time.
Terminating more than one source
signal to a single channel simulta-
neously will result in unsatisfactory
performance.