1
Figure
: Wiring diagram
1/2. 12 VDC
3.
LED indication
4.
Integrator level
5/6. Alarm output
2
Figure
: Two ways to test the seismic detectors
Test disabled (ex-factory setting)
1
Internal test of detector's electronics = Position jumper
2
between 1 and 2 .
Function test of the detector and its physical contact with the
3
protected object = Position connector from test transmitter
VT705P between 2 and 3.
!
Connecting terminal 10 to 0 V activates both tests.
Figure
3
: General characteristics of the VV600/602
Plus
1.
Cover
2.
Cover screw
3.
Base plate
4.
Mounting holes
5.
Clamp
6.
Area for mounting the VT705P test transmitter
7.
Potentiometer for adjusting the detector's sensitivity
8.
Connection block
9.
Anti-tamper micro-switch
10. Mounting plate VM600P
11. Fixing bolt
12. Expander bolt
13. Test transmitter VT705P
Using the mounting plate VM600P as a template
A. Holes for VV600/602 Plus
B. Holes for Securitas SSD70
C. Holes for Cerebus GM31/35/550/560
D. Hole for expansion plug or recess mounting box
E. Holes for Securitas 2000
F.
Template and mounting holes for test transmitter VT705P
G. Holes for accessories.
Detection range (in meters):
Material
Sensitivity
setting
Concrete
Steel
1/G
max
Brick
Concrete
Steel
2/G
ref
Brick
Concrete
Steel
3/G
min
Brick
Concrete
Steel
4
Brick
Concrete
Steel
5
Brick
7.
Spare
8/9. Tamper
10. Test control
11. Spare
Thermal
Diamond
lance
disk
4
14
8
14
3
8
3
9
4
9
1
6
2
6
2
6
-
4
1
5
1
5
-
3
-
4
-
4
-
2
GB
4
Figure
5
Figure
First weld points 1, 2, 3, and 4. Then weld seams 5 and 6.
6
Figure
Always use a VM600P mounting plate. The expansion plug must
penetrate at least 50 mm into the concrete. Please follow the
steps shown in Figure 6 if you are installing the test transmitter
VT705P.
!
For the equipment to conform to CEI standard 79-2, the
VT705P test transmitter must be installed.
7
Figure
Using a voltmeter, check the background signal level in the
detector to prevent nuisance alarms. Set the sensitivity to Gmax
during the test.
VV600 Plus
0.7 V
1.4 V
!
Try to remove the source of ambient noise instead of
reducing the range.
Functional testing with hand tester VT610P
#
tool
:
VV600 Plus
Alarm in 30 sec.
Alarm after 5 blows
Technical specifications:
Input power:
Drilling
Current
14
consumption:
14
Alarm output:
8
9
Alarm indication:
9
Sensitivity:
6
Range:
6
Sabotage protection:
6
4
5
Low voltage alarm:
5
3
Temperature limits:
4
Dimensions:
4
Colour:
2
Weight:
- 3 -
: Mounting the detector directly on a
metal surface without using a mounting
plate
: Mounting the detector on a metal
surface using the VM604P weld-on plate
: Mounting on concrete
: Control and function test
VV602 Plus
Measure
0 V
None
2 V
Reduce range/remove source
VV602 Plus
Alarm in 45 sec.
NA
9-15 VDC
2 V max. ripple pp
Nom. 8.6 mA
Form A solid state relay, max. series
resistance 35 Ohm
LED-ind. output 3
5 steps of 6 dB each
See Table "Detection range"
Temp. 84°C,
drill shield,
opening/pry-off contact,
7.5 V
-20°C to +55°C
101 x 81 x 28 mm
Grey, RAL 7035
380 g
"
and mechanical