Troubleshooting and
Warranty Procedure
1. If the unit will not turn on, it is not getting power. Check power cord instal-
lation and connectors. Check 2 amp fuse on power cable and replace, if
necessary.
2. If the meter displays 00.0 at all times (while baling), there is an open circuit
between the display module and the sensor. Check that the cable is not
damaged and that the connector is plugged securely. The connector may
be corroded and need replacing. Also check that the sensor cable ring ter-
minals are fastened tightly to the electrode posts. (The meter should still
read about 12.0 when recalibrated, even if there is an open circuit to the
sensor.)
3. If the meter displays 99.9 at all times (while baling), there is a short in the
sensor cable or at the electrodes. (The meter will not read 12.0 when reca-
libration is attempted, but will always display 99.9). Check for cable dam-
age.
4. If the meter displays 8.0 when the bale chamber is empty, electrodes are
dirty and need cleaning. (The meter will also read 99.9 when recalibration
is attempted, if electrodes are dirty.) Clean and recalibrate.
5. If all else fails, please read this manual again! Carefully.
Warranty
The Agratronix BHT-1 Hay Moisture Tester is guaranteed to be free from
defects in materials and workmanship for one year from date of retail pur-
chase. This warranty does not cover the battery or damage resulting from
misuse, neglect, accident or improper installation or maintenance. This
warranty does not apply to any product which has been repaired or altered
outside the factory.
The foregoing warranty is exclusive and in lieu of all other warranties of
merchantability, fi tness for purpose and any other type, whether expressed
or implied. Agratronix neither assumes nor authorizes anyone to assume
for it any other obligation or liability in connection with its product and will
not be liable for consequential damages.
7