Descargar Imprimir esta página

Allmatic SER 20 Manual De Instrucciones página 16

Publicidad

Idiomas disponibles

Idiomas disponibles

G
B
R
OLLING SHUTTER WITH LENGHT SHAFT OVER 4 MT
In this case we suggest to mount 2 SER on the same shaft at the shutter
extrimities. It is necessary to eliminate the limit switch of one of the 2 SER
and connect in parallel the two motors.
SER without limit switches
=
IMPORTANT
3 wires cable to connect the two operators
I
MPORTANT!
When mounted with engine on the left all the operations are inverted
and limit switch F1 becomes F2
1 - Cam for end travel
2 - Screw for blockage of the limit switches
F1- Screw for regulation of limit switch which stop the upward movement
F2- Screw four regulation of limit switch which stop the downward movement
For the regulation of the electrical limit switches tighten the two blue screw
and unscrew or tighten the wheels F1 and F2.
To mantain the desired position of the switches you must block the two
screws when the regulation is completed.
A
TTENTION:
Avoid all the manouvres of the motor really not
necessary during the regulation. Many manouvres
at the same time cause the intervention of the
thermal sensor.
R
EGULATION OF THE LIMIT SWITCH WHICH STOPS THE DOWNWARD MOVEMENT
When there is too little
travel tighten F1
R
EGULATION OF THE LIMIT SWITCH WHICH STOPS THE UPWARD MOVEMENT
6-1624000 REV. 09 DEL 05/03/13
Ground
When there is too little
travel unscrew F2
IMPORTANT: Before fixing the two pulleis to the shutter laminate (4),
verify that the sense of rotation of the 2 SER is the same.
SPRINGS
Ground
When there is too much
travel unscrew F1
When there is too much
travel tighten F2
16
16
SER with limit switches
=
IMPORTANT
Ground
When adjustement is complete
tighten the 2 blocking screw
When adjustement is complete
tighten the 2 blocking screw
4
5
6
7

Publicidad

loading

Este manual también es adecuado para:

Ser 22Ser 22 sSer 24