Thermostat; Operator Maintenance Instructions; Troubleshooting - Enerco HEATSTAR HS4030 Instrucciones De Funcionamiento Y Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

THERMOSTAT

12. START-UP PROCEDURE
OPEN­THE­GAS­SUPPLY­VALVE­OR­VALVES.­
Set­the­thermostat­to­the­OFF­position.­See­
Figure­5.­If­the­manual­gas­control­knob­
on­the­gas­valve­is­not­in­the­OFF­position,­
partially­depress­the­knob­and­rotate­to­the­
OFF­position.­See­Figure­6.
Wait­5­minutes­to­allow­gas­that­may­have­
accumulated in the main burner to escape
(especially­important­after­installation).
Turn­the­manual­gas­control­knob­to­the­PILOT­position.
Depress­the­manual­gas­control­knob.­Using­a­match,­light­the­
pilot­light.­See­Figure­6.­Hold­the­knob­down­for­approximately­
30­seconds­to­allow­any­air­in­gas­lines­to­pass­through­pilot­and,­
once the pilot is lit, allow the thermocouple to heat up enough to
activate­the­safety­valve­in­an­open­position.
MANUAL­GAS­
PRESSURE­REGULATOR­
CONTROL­KNOB
ADJUSTMENT
WRENCH­
BOSS
GAS­INLET
PILOTSTAT­POWER­
PILOT­FLOW­
UNIT
ADJUSTING­
SCREW­
Figure 6. Gas Valve
(BENEATH­
COVER­SCREW)
Components
Release­manual­gas­control­knob­and­turn­to­ON.­Reset­
thermostat to desired temperature.
NOTE:
During­the­initial­startup­of­the unit­an­odor­and,­perhaps,­some­
vapor­will­come­from­the­heater.­This­is­the­gasket­binding­
material­emitting­this­odor­and/or­vapor.­After­approximately­20­
minutes this odor will disappear and not occur again.
13. SHUTDOWN
1.­ Turn­thermostat­to­OFF.
2.­ Turn­manual­gas­control­knob­on­gas­valve­to­PILOT­
position.
3.­ Partially­depress­knob­and­rotate­to­the­OFF­position.
4.­ Close­gas­supply­valves.
Enerco Group, Inc. |Gas-Fired Infra-Red Space Heaters
Figure 5.
Thermostat
controls
STANDARD­
PRESSURE­
REGULATOR
(Incoming pressure
not exceed 13" W.C.)
PILOT­GAS­
OUTLET­
(PRESSURE­
TAPPING­
DIRECTLY­
BENEATH)
14. OPERATOR MAINTENANCE
INSTRUCTIONS

1. TROUBLESHOOTING

a.­­Table­4­lists­system­issues­which­may­occur­during­the­
operation or maintenance of your heater.
b.­­ In­the­event,­results­cannot­be­obtained­after­perform-
ing­all­listed­solutions,­call­your­Mr.­Heater­dealer,­or­the
factory­customer­service­department­at­1-866-447-2194.
2. ADJUSTING THE PILOT FLAME
The­pilot­flame­should­envelope­­
3/8­to­½­in.­(10­to­13mm)­of­the­­
tip of the thermocouple or
generator.­To­adjust­the­pilot­­
flame:
a.­­Remove­pilot­adjustment­
­
cover­screw.­Refer­to­Figure­8.
b.­­Turn­inner­adjustment­screw­clockwise­
­
to­decrease­or­counterclockwise­to­
increase pilot flame.
c.­­Always­replace­cover­screw­after­adjustment­and­tighten­
firmly to ensure proper operation.
Pressure regulator
adjustment­(beneath­
Manual gas
cover­screw)
control­knob
Wrench­
boss
Gas­
inlet
Pilotstat
Pilot flow adjusting screw
power unit
(beneath­cover­screw)
13. REPLACING THE GAS VALVE UNIT
a.­­Remove­the­two­gas­valve­unit­wires­at­the­gas­control­
valve­labeled­"PP."
b.­­Unscrew­gas­valve­from­gas­piping.
c.­­Reconnect­gas­valve­and­unit­wires­to­terminals­"PP."­Be­
sure­to­leave­thermostat­wire­on­one­terminal.
15. FREQUENCY OF OPERATOR CHECKS
Intermittent Use
Appliances­that­are­used­seasonally­should­be­checked­before­
shutdown­and­again­before­the­next­use.
Dusty,­wet­or­corrosive­environment.­Since­these­environments­can­
cause the gas control to deteriorate more rapidly, the system should
be­checked­more­often.
The gas control should be replaced if:
a.­­It­does­not­perform­properly­on­checkout­or­
troubleshooting.
b.­­The­gas­control­knob­is­hard­to­turn­or­push­down,­or­it­
fails­to­pop­back­up­when­released.
E6
Operating Instructions and Owner's Manual
­
­
­
­
­
­
­
­
­
Install­long­
screw in
outside corner
Figure 8.
Top view
Standard
of standard
pressure
capacity gas
regulator
("A"­model)
control.
Step
opening
Pilot gas
regulator
outlet
("C"­model)
(pressure­
tapping
directly
beneath)

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido