Electrical Connections And Equipotential Bonding; Connection To Waterworks - OFFCAR 900 Serie Instrucciones De Instalación, Uso Y Mantenimiento

Ocultar thumbs Ver también para 900 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

2.2.1. ELECTRICAL CONNECTIONS AND EQUIPOTENTIAL BONDING

Warning! : The appliance is supplied to operate according to the power supply
indicated on the data plate.
− As mentioned, the appliance must be connected to the power supply by way of a
multiple pole main isolating switch and protection device, that must be proportioned to
the power of the appliance (1 mA per kW of rated power).
− The earthing system must be efficient.
− As this appliance is a type X equipment (delivery without power cable and plug), the
cable and other hardware needed to make the connection to the electrical power
supply must be provided by the installer.
− The power cable shall be of the kind described in the paragraph "Technical data" and
shall be resistant to oil.
Proceed as follows to reach the power supply terminal board:
-
Disconnect the appliance using the switch placed before the appliance.
-
Remove the fron panel, unloosing the two fixing screws.
Remove the lid of the housing protecting the electrical components.
-
− The cable must be fed in from beneath the clamp. The individual wires are then
fastened to the corresponding terminals of the terminal board. The earth wire must be
longer than the other wires, so that in the event of the cable being jerked or the clamp
broken, the live wires will disconnect first. Lock the cord fastener.
− The appliance must incorporate an equipotential system.
− Connect the terminal on the lower right-hand side marked with the international symbol a
connector with a nominal cross section <10 mm
system of the building shall be connected like this.
− Water inlet pressure must be between 50 and 300 kPa, otherwise install a pressure
regulator on the line before the appliance.
− Install a cut-off valve for each supply on the line before the appliance.
− Make connections according to regulations currently in force.
− Water connections to 10mm. are fitted in the lower part on the left-hand side of the
appliance.
Instruction manual for installation, maintenance and use
Electric tilting cooker Serie 900

2.2.2. CONNECTION TO WATERWORKS

2
. All the appliances installed and the earth
- GB -
9 di 28
Page

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

80bre80i90bre90i90bre12i90bre15i

Tabla de contenido