Main structure in AISI 430 with 4 adjustable height feet.
−
Panels in stainless steel AISI 304, thickness 10-12/10.
−
Cooking vat in stainless steel AISI 316, thickness 20/10.
−
Chrome-plated brass drainage tap.
−
Lid in stainless steel, hinged and spring balanced in all opening positions.
−
Jacket and lining in stainless steel AISI 304, thickness 15-20/10.
−
Heating system comprising shielded heating elements made from "Incoloy-800" alloy with boiler and
steam circulation.
−
Jacket pressure is controlled by a safety valve set at 0.5 bar; the appliance is equipped with an analogue
pressure gauge.
−
The cold water connection is 10 mm.
−
The hot water connection is 10 mm.
−
Safety thermostat to interrupt operation automatically in case of failures.
−
The appliance is equipped with a three-position selector with three heating functions:
−
position "0" Heating not activated
−
position "I"
Reduced power 50%
−
position "2" Full power 100%
−
Operating thermostat.
1.4. LAWS, TECHNICAL PRESCRIPTIONS AND DIRECTIVES
When installing the appliance it is necessary to follow and comply with the following regulations:
−
current regulations on the matter;
−
any hygienic-sanitary regulations concerning cooking environments;
−
municipal and/or territorial building regulations and fire prevention prescriptions;
−
current accident prevention guidelines;
−
electricity board regulations concerning safety;
−
the regulations of the electrical power supply company or agency;
−
any other local prescriptions.
1.5. SPECIAL REQUIREMENTS FOR THE INSTALLATION SITE
−
The room in which the appliance is to operate must be well ventilated.
−
In addition, it is good policy to locate the appliance under an extractor hood so that cooking vapours can
be removed rapidly and continuously.
−
Current regulations require the installation of a multiple pole switch between the appliance and the
electrical power supply; the switch must have a contact gap of least 3 mm on each pole.
−
This appliance requires two water connections: one for hot and one for cold water. Each line must be
fitted with an on-off valve.
Warning! :
The electrical isolating switch and the water shutoff valves must both be located near
to the appliance, within easy reach for the user.
Manuale d'istruzione per l'installazione, la manutenzione e l'uso
Pentole elettriche PI50-78ET
1.3. CONSTRUCTION
05.10.01
pagina
- IT
24