MANTENIMIENTO.
El grupo A2410 lleva instalado un led rojo cuya funcionalidad es la siguiente:
Group A2410 comes with a red LED with the following functions:
The LED is off: Group A2410 is idle.
The LED is on without blinking: Group A2410 is active, that is to say, there is a call in progress.
The LED blinks at 1 second interval: It is a main panel with a secondary panel that is active.
The LED blinks 4 times a second: Installation error. There is more than one A2410 group configured as
the main one or there are none configured as the main one.
SOLUCIÓN DE PROBLEMAS.
PROBLEMA
PROBLEM
No funciona nada.
Nothing works.
No aparece la imagen en el
monitor.
No image appears on the
monitor.
MAINTENANCE.
PROBLEM SOLVING.
POSIBLE FALLO
POSSIBLE FAULT
±
Check the voltages between terminal blocks 1-2 (12 VAC) and between
11-5F (16VDC±1VDC) in the power supplies. If there are problems with
any of these outputs, disconnect the PRIM cables, wait for one minute
and reconnect them. Should the problem persist, check the installation
connections.
Check connection cables 11-5 (16VDC± 1VDC) in the monitor. There
should be 12 VDC between terminal blocks 14 and 5F of the camera
module when the monitor is switched on. The video signal cable (coaxial
or twisted pair) must be connected correctly. Verify there is a connector
between the audio module and the camera module in the street panel.
In the case of there being video distributors in the installation, check
they have correct power supply.
±