Specifications
Specifications are subject to change without notice.
Specification
Measurement range (pH)
Measurement range (temperature)
Resolution
Temperature compensation
Accuracy (analyzer only)
Repeatability (analyzer only)
Stability (analyzer only)
Maximum probe immersion depth/ pressure Submersible to 107 m (350 ft)/1050 kPa (150 psi)
Operating temperature
Storage temperature
Dimensions (length/diameter)
Cable lengths/type
Maximum transmission distance
Calibration methods
Interfaces
Material

General information

In no event will the manufacturer be liable for direct, indirect, special, incidental or consequential
damages resulting from any defect or omission in this manual. The manufacturer reserves the right to
make changes in this manual and the products it describes at any time, without notice or obligation.
Revised editions are found on the manufacturer's website.

Safety information

The manufacturer is not responsible for any damages due to misapplication or misuse of this product including,
without limitation, direct, incidental and consequential damages, and disclaims such damages to the full extent
permitted under applicable law. The user is solely responsible to identify critical application risks and install
appropriate mechanisms to protect processes during a possible equipment malfunction.
Please read this entire manual before unpacking, setting up or operating this equipment. Pay
attention to all danger and caution statements. Failure to do so could result in serious injury to the
operator or damage to the equipment.
Make sure that the protection provided by this equipment is not impaired. Do not use or install this
equipment in any manner other than that specified in this manual.

Use of hazard information

Indicates a potentially or imminently hazardous situation which, if not avoided, will result in death or serious injury.
Details
0 to 14 pH
0 to 105 °C (32 to 221 °F)
0.01 or 0.1 pH
Pt 1000 ohm RTD
0.1% of span
0.1% of span or better
0.05% or span per 24 hours, non-cumulative
0 to 105 °C (32 to 221 °F)
–30 to 70 °C (–22 to 158 °F); 0 to 95% relative humidity, non-
condensing
149.9 mm (5.9 in.)/7.62 mm (1.30 in.)
4.6 m (15 ft)
914 m (3000 ft)
Initial 2-point calibration using 2 buffers and then option to use 1-
point or 2-point (slope) calibration using samples or buffers
Modbus from gateway
Corrosion-resistant materials, fully-immersible probe
N O T I C E
D A N G E R
English 3