Indoor Unit Installation Diagram - Daikin CTXG09QVJUW Manual De Instalación

Ocultar thumbs Ver también para CTXG09QVJUW:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Indoor Unit Installation Diagram

CAUTION
• Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.
• Do not place large objects near the INTELLIGENT EYE sensor. Also keep heating units or humidifiers outside the sensor's
detection area.
The
A
mounting plate should
be installed on a wall which
can support the weight of the
indoor unit.
1-3/16" (30mm) or more
from ceiling
1-15/16" (50mm) or more
from walls (on both sides)
Air filters
C
Titanium apatite photocatalytic
air-purifying filter (2)
Filter frame
Titanium apatite
photocatalytic
air-purifying filter
Tab
Claw
English
A Mounting plate
B
Mounting plate fixing
screws M4 × 1" (M4 × 25mm)
J
Screw covers
Lower front panel
Make sure that there are no
obstacles within 19-11/16 inch
(500mm) under the signal
receiver.
Such obstacles, if any, may have
an adverse influence on the
reception performance of the
receiver and the reception
distance may be shortened.
Service lid
The service lid is removable.
Opening method
1) Remove the service lid screws.
2) Pull out the service lid diagonally
down in the direction of the arrow.
3) Pull down.
Air filter
How to attach the indoor unit
Hook the hooks of the bottom
frame to the
A
mounting plate.
If the hooks are difficult to hook,
remove the front grille.
How to remove the indoor unit
Push up the lower part of the
front grille to release the hooks.
If it is difficult to release, remove
the front grille.
Upper front panel
19-11/16" (500mm)
or more
F Remote controller holder
Front grille
Bottom frame
Screws M4 × 5/8" (M4 × 16mm)
When dismounting the front grille, refer
to "2. Removing and installing the front grille"
on page 11.
INTELLIGENT EYE sensor
Cut thermal insulation pipe to an
appropriate length and wrap it with tape,
making sure that no gap is left in the
insulation pipe's cut line.
Wrap the insulation pipe with the
finishing tape from bottom to top.
D Wireless remote controller
Before screwing the
remote controller
E
holder to the wall,
make sure that
control signals are
properly received
by indoor unit.
E Remote controller
holder
fixing screws
M3 × 13/16" (M3 × 20mm)
A Mounting
plate
Hook
4