Indoor Unit Installation Drawings

Mounting plate
Mounting plate
fixing screw
(field supply: M4 × 25L)
Front panel
50mm or more
from walls
(on both sides)
Air filters
Filter frame
Air filter
Tab
4
The mounting plate
should be installed on a
wall which can support the
weight of the indoor unit.
30mm or more from ceiling
Screws
(M4 × 16L)
Opening the service lid
The service lid is removable.
Opening method
1) Remove the service lid screw.
(2 pcs)
2) Pull out the service lid diagonally
down in the direction of the arrow.
3) Pull down.
How to attach the indoor unit
Hook the claws of the bottom frame
to the mounting plate.
If the claws are difficult to hook,
remove the front grille.
How to remove the indoor unit
Push up the lower part of the front
grille to release the claws.
If they are difficult to release,
remove the front grille.
Service lid
Bottom frame
Front grille
Caulk pipe
Cut thermal insulation
hole gap
pipe to an appropriate
with putty.
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipe's cut line.
Wrap the insulation pipe
with the finishing tape
from bottom to top.
Wireless remote controller
Fixing screw for remote
controller holder
(field supply: M3 × 20L)
Mounting
plate
Claw
Before screwing the
remote controller holder
to the wall, make sure
that control signals are
properly received by
indoor unit.
Remote controller
holder