Changing SWITCH OUT Terminal to Momentary,
Independent of S1 position. (Figure 6 on page 12)
To accommodate interface equipment requiring momentary clo-
sure of the microphone (even when the desired microphone func-
tion is latching on/off), proceed as follows:
Remove R45 from the top of the circuit board.
1.
Reinstall R45 at location R46 on the top of the circuit
2.
board.
DESIRED MICROPHONE FUNCTION
Push to Mute (As Shipped)
Push to Talk
Push On/Push Off
Switch Deactivated, Mic Always Active
Switch Deactivated, Mic Always Active
Automatic Mixer Mode
SPECIFICATIONS
Frequency Response (Figure 3 on page 11)
50 to 17,000 Hz
Polar Pattern (Figure 4 on page 11)
Output Impedance (at 1,000 Hz)
Rated at 150 Ω (180 Ω actual)
Open Circuit Sensitivity
At 1 kHz, ref. 1 V per Pascal*
Cardioid:-33.5 dBV (21.1 mV)
Supercardioid:-32.5 dBV (23.7 mV)
Omnidirectional:-28.0 dBV (39.8 mV)
* 1 Pascal=94 dB SPL
Maximum SPL (1kHz at 1% THD, 1 kΩ load)
Cardioid:123.0 dB
Supercardioid:122.0 dB
Omnidirectional:117.5 dB
Equivalent Output Noise (A-weighted)
Cardioid:29.0 dB SPL
Supercardioid:28.0 dB SPL
Omnidirectional:70.5 dB SPL
Signal to Noise Ratio (referenced at 94 dB SPL)
Cardioid:65.0 dB
Supercardioid:66.0 dB
Omnidirectional:70.5 dB
Dynamic Range with 1 kΩ load
94.0 dB
Common Mode Rejection
45.0 dB minimum
Mute Switch Attenuation
50.0 dB minimum
Preamplifier Output Clipping Level (1% THD)
-6.0 dBV (0.5 V)
Polarity
Positive sound pressure on diaphragm produces positive voltage
on pin 2 relative to pin 3 of XLR output connector.
Custom Switch Modifications
S4 is available for custom logic modifications. When S4 is in the
ON position, pad W4 is connected to pad W5.
SHURE, the Shure logo, and MICROFLEX are registered trade-
marks of Shure Incorporated.
USER ACTION/LED DISPLAY
Press and hold switch to temporarily mute
microphone; release switch to unmute
LED turns on when microphone is active
Press and hold switch to activate microphone;
release switch to mute
LED turns on when microphone is active
Press switch to toggle microphone on or off
LED turns on when microphone is active
No action, LED Always OFF
Short LED IN terminal to LOGIC GROUND terminal
LED Always ON
If S1=OFF, SWITCH OUT signal will be momentarily
logic low when switch is pressed
If S1=ON, SWITCH OUT signal will be latching logic
low when switch is pressed
Connect SWITCH OUT signal to various logic inputs
of automatic mixer for custom functions
Connect mixer channel GATE OUT to microphone
LED IN. LED on microphone turns on when its
channel is gated on
Power Requirements
Environmental Requirements
Dimensions (Figure 5 on page 12)
Weight
Cable Type (Figure 7 on page 12)
CERTIFICATION
FURNISHED ACCESSORIES
OPTIONAL ACCESSORIES
REPLACEMENT PARTS
2
S1 = OFF
S2 = OFF
S3 = OFF
S1 = OFF
S2 = ON
S3 = OFF
S1 = ON,
S2 = ON for muted initial state
S2 = OFF for active initial state
S3 = OFF
S3 = ON
S3 = ON
S1 = ON or OFF
S3 = ON
11 to 52 Vdc phantom, 2.0 mA
Operating Temperature Range: -18° to 57° C (0° to 135° F)
Relative Humidity: 0 to 95%
MX412D: 0.81 kg (1.80 lbs.) net, 1.63 kg (3.62 lbs.) packaged
MX418D: 0.82 kg (1.82 lbs.) net, 1.64 kg (3.64 lbs.) packaged
The attached custom cable contains a shielded audio pair and
three unshielded conductors for logic control.
Overall diameter=0.6 mm (0.165 in.)
Eligible to bear CE Marking. Conforms to European EMC Direc-
tive 89/336/EEC. Meets applicable tests and performance criteria
in European Standard EN55103 (1996) parts 1 and 2, for residen-
tial (E1) and light industrial (E2) environments.
Snap-Fit Foam Windscreen
(1 furnished, 4 in replacement kit) .............................RK412WS
Foam Ball Windscreen................................................... A99WS
Locking Metal Windscreen........................................ A412MWS
Custom Logic Cable (specify length) ............................. 15A525
Omnidirectional Cartridge ............................................... R183B
Supercardioid Cartridge.................................................. R184B
Cardioid Cartridge........................................................... R185B
DIP SWITCH SETTINGS

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Microflex mx412dMicroflex mx418d

Tabla de contenido