PROCESO DE TENSADO (1/2) / TENSIONING PROCEDURE (1/2)
PROCESO DE TENSADO (1/2)
1. SITUAR LA CABEZA A 7mm DEL TOPE IZQUIERDO, Y PONER EL VISUALIZADOR A 0.
2. MOVER LA CABEZA AL OTRO EXTREMO DEL CURSO DE MEDICION (MINIMO A 8 mm
DEL TOPE DERECHO).
3. APUNTAR LA MEDIDA QUE NOS DA EL VISUALIZADOR (EJEMPLO L=7440,892 mm
PARA UN CURSO DE MEDICIÓN = 7440).
4. PONER EL VISUALIZADOR A 0.
5. CALCULAR
EL
VALOR
A
TENSAR
T=(L+47.25)x0.120 DONDE T ES EL VALOR EN MICRAS QUE DEBE MOSTRAR EL
VISUALIZADOR DESPUES DE TENSAR, EN ESTE EJEMPLO:
T=(L+47.25)x0.120=(7440.8928+47.25)x0.120=896 MICRAS.
SEGUN
LA
SIGUIENTE
FORMULA
EXT v1503 - page/página 15/26
TENSIONING PROCEDURE (1/2)
1. POSITION THE READER HEAD 7mm FROM THE LEFT END AND SET THE DRO TO 0.
2. MOVE THE READER HEAD TO THE OTHER END OF THE MEASURING LENGTH (AT
LEAST 8 mm FROM THE RIGHT END).
3. JOT DOWN THE MEASUREMENT DISPLAYED BY THE DRO (FOR EXAMPLE
L=7440,892 mm FOR A MEASURING LENGTH = 7440).
4. SET THE DRO TO 0.
5. CALCULATE THE TENSION VALUE WITH THE FORMULA T=(L+47.25)x0.120 WHERE T
IS THE VALUE IN MICRONS THAT THE DRO MUST DISPLAY AFTER THE BAND HAS
BEEN TENSIONED, IN THIS EXAMPLE:
T=(L+47.25)x0.120=(7440.8928+47.25)x0.120=896 MICRONS.