Led Indicators - Morningstar ProStar-15 Manual Del Operador

Controladores de sistemas fotovoltaicos
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CHARGING (LED 1 – green)
ON: battery charging during sunlight (always on during sunlight)
OFF: normal during night (off during sunlight indicates solar reverse
polarity or overcurrent)
BATTERY STATUS (LEDs 2 – 4)
GREEN:
YELLOW: ON indicates battery at middle capacity
RED:
FAULT INDICATIONS (G = green; Y = yellow; R = red)
G/Y/R blinking together – Battery select fault
R – Y sequencing
R – G sequencing
R/G – Y sequencing
Remote Temperature Sensor – To improve battery charging, an
optional remote temperature sensor can be soldered to the ProStar
assembly on the main board at J-12.
Telecom Noise Jumper – Noise over telecom equipment may be
eliminated by cutting a vertical resistor in the upper right hand corner
of the board, identified at J-11. This will convert the battery charging
to a typical "on-off" regulation of the solar energy.
OPTIONAL DIGITAL METER & MANUAL DISCONNECT
MANUAL DISCONNECT:
LOAD OFF: A brief push of the button (less than 2 seconds) will
disconnect the Load. The Solar remains on and charging.
LOAD AND SOLAR OFF: If the button is held down for 2 seconds,
the Solar will also be disconnected.
Digital Display – A precision 3-digit digital meter will continuously
display battery voltage, solar current, and the load current. The meter
automatically scrolls through these 3 displays. The 3 red LEDs will
indicate which parameter is being displayed.

LED INDICATORS

ON indicates battery is near full charge
BLINKING indicates PWM charging (regulation)
BLINKING indicates a low charge state and a low
voltage load disconnect (LVD) warning
ON indicates the load has been disconnected (LVD)
– High temperature disconnect
– High voltage disconnect
– Load short circuit or overload
6