Electric Connections - Quick TCD 1022 D Manual De Instalacion Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

INSTALLATION
GB

ELECTRIC CONNECTIONS

The control panel complies with EMC standards (electromagnetic compatibility) but requires correct installation
to avoid compromising its performance and that of the surronding instruments.
For this reason the interface wires must be positioned at a distance of at least:
• 1 m away from cables that transmit radio signals (except for SSB radio transmitters).
• 2 m away from cables for SSB radio transmitter signals.
Follow the rules below to construct the electrical installation relative to the control panel:
• Connect the controls connector to the connector coming from the thruster.
• Put in a switch to turn on and shut off the instrument (not supplied).
• Position the switch so that it is within easy reach should it be necessary to shut off the instrument in an emer-
gency.
• Insert a 4A quick-acting fuse on the controls power supply line (not supplied).
• Use wires, for the remote control power supply, with a correct cross section according to their length.
• Do not use voltage from the motor or thruster battery circuit for the control panel.
• Before switching on the power to the control, check that all the electrical connections are correct.
ELECTRICAL CONNECTIONS DIAGRAM
TCD 1042
RED
BLACK
FUSE
*
TO THE SERVICE
BATTERY
*
Common negative for the battery groups.
16
RED
BLACK
CONTROL CABLE
EXTENSIONS
(OPTIONALS)
TCD 1022
MOTOR
SPLITTER
(OPTIONAL)
BATTERY ISOLATOR
FUSE
*
BATTERY
12/24 V
TCD1022 D/1042 D - REV004A

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tcd 1042 dTcd 1022 eTcd 1042 eThruster command tcd 1022 dThruster command tcd 1042 d

Tabla de contenido