To Replace Regulator - Porter Cable CPFC2TV3525VP Manual De Instrucciones

Compresor de aire, sin aceite
Ocultar thumbs Ver también para CPFC2TV3525VP:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

10. Apply sealant to the check valve
threads. Reinstall the check valve
(turn clockwise).
11. Replace the pressure release
tube. Tighten nut.
12. Replace the outlet tube and tight-
en nut.
13. Replace the shroud and air filter.
14. Perform the Break-in Procedure.
See "Break-in Procedure" in the
"Operation" section.

TO REPLACE REGULATOR

1.
Release all air pressure from air
tank. See "To Drain Tank" in the
"Maintenance" section.
2.
Set the On/Auto/Off lever to "Off"
and unplug unit.
3.
Remove the outlet pressure
gauge and quick connect (if
equipped) from the regulator.
Regulator
4.
Remove the regulator.
5.
Apply pipe sealant tape to the
nipple.
Outlet
Pressure
Gauge
Quick
Connect
Nipple
17 - ENG
6.
Assemble the regulator and orient
as shown.
Regulator
NOTE: Arrow indicates flow of air.
Make sure it is pointing in the direction
of air flow.
Regulator
Arrow
7.
Reapply pipe sealant to outlet
pressure gauge and quick con-
nect.
8.
Reassemble outlet pressure
gauge and quick connect. Orient
outlet pressure gauge to read cor-
rectly. Tighten quick connect with
wrench.
D21683

Publicidad

Tabla de contenido
loading

Tabla de contenido