4
ANYBUS MODULE SPECIFICATIONS
4.1
PROFIBUS DP-V1
4.1.1
Front panel and diagnostic
1
4.1.2
1 – Operation mode LED
Status
Off
Not online / no power.
Green
On-line, data exchange.
Flashing green On-line, clear.
Flashing red
Parametrization error.
(1 flash)
Flashing red
Profibus configuration error.
(2 flashes)
4.1.3
2 – Module status LED
Status
Off
No initialized.
Green
Initialized.
Flashing green Initialized, diagnostic event(s) present.
Red
Exception error.
4.1.4
3 – Profibus connector
Pin
Signal
1
-
2
-
3
B line
Positive RxD / TxD, RS485 level.
4
RTS
Request to send.
5
GND bus Ground (isolated).
+5V Bus
+5V termination power (isolated,
6
output
short circuit protected).
7
-
8
A line
negative RxD/TxD, RS485 level.
9
-
Internally connected to the An-
Cable
ybus protective earth via cable
housing
shield
shield filters according to the
Profibus standard.
20
5
1
2
3
9
6
Indication
Indication
Value
-
-
-
-
4.1.5
ROT2 – Node address.
Pos.
0
SSA (Select Slave Address).
1 ÷ 9
4.1.6
ROT3 – Unused.
Set to 0 position.
Value
Profibus Id.
3.300.139/B