9.4.
Setting the air inlet on the burner
Follow these instructions.
1. Close the gas valve.
2. Remove the gas control knob (A).
3. Loosen the screws (B) and remove the control
panel (C).
B
ID 16
9.5.
Replacement of the ignition flame nozzle
Follow these instructions.
1. Close the gas valve.
2. Remove the gas control knob (A).
3. Loosen the screws (B) and remove the control
panel (C).
4. Ignition flame is located near the burner.
B
4. Loosen the screw (D) and set the sleeve (E)
5. Finally, set the device to the initial status.
D
A
C
E
5. Loosen the nut (D).
6. Take out and replace the nozzle.
7. Retighten the nut and set the device to the
8. Adjust with a screw (E).
A
C
15
ENGLISH
depending on the type of used gas (see table
in attachments).
initial status.
E
H
GB
D
E