10. TROUBLESHOOTING

Before starting to look for faults it is necessary to disconnect the power supply to the pump (take the plug out of
the socket)
Fault
The pump does not start.
The pump does not start.
The pump does not start.
The pump does not stop.
Insufficient delivery.
LED
Probable Causes
Red: off
No electric power.
White: off
Blue: off
Red: on
Shaft blocked.
White: on
Blue: off
Red: off
Utility at a level higher than the system
White: on
restarting pressure level (par. 3.2).
Blue: off
Red: off
1.
White: on
2.
Blue: off
3.
4.
Red: off
1. Suction depth too high.
White: on
2. Suction pipe clogged or diameter
Blue: off
3. Impeller or hydraulic part clogged.
ENGLISH
Figure 9
Leak in the system.
Impeller or hydraulic part clogged.
Air getting into the suction pipe.
Faulty flow sensor.
insufficient.
21
Remedies
Check whether there is voltage
in the socket and insert the
plug again.
See paragraph 9.4 (motor shaft
maintenance).
Increase the system restarting
pressure level by increasing
SP or decreasing RP.
1. Check the system, find and
eliminate the leak.
2. Dismantle the system and
remove
the
obstructions
(assistance service).
3. Check the suction pipe, find
and eliminate the cause of
air getting in.
4. Contact
the
assistance
centre.
1. As
the
suction
increases
the
hydraulic
performance of the product
decreases. Check whether
the suction depth can be
reduced. Use a suction pipe
with a larger diameter (but
never smaller than 1").
2. Check the suction pipe, find
the
cause
of
choking
(obstruction,
dry
counterslope..) and remove
it.
3. Dismantle the system and
remove
the
obstructions
(assistance service).
depth
bend,