Atlanta Attachment Company 211ES Manual Del Usuario página 34

Tabla de contenido

Publicidad

Technical Manual & Parts Lists
3. Setting The Lower Looper
(Fig. 3)
Insert looper A in the looper
holder positioning it at the top
with calibrator 315910-0-00
(supplied with all the machines)
to obtain dimension W (see
value on phase sheet Pg. 31)
which represents the distance
between the back looper and the
bottom of the needle plate.
Block it at the reference level of
the leg with screw B. Check
that the measurements
correspond with those in the
phase instructions (attached to
the machine).
In the case of need to carry out
corrections, operate as follows:
A. To obtain dimension "b" (Fig. 4)
move the looper to the extreme
right, slacken screw L (Fig. 5) of
clip M and operate on the N rod
of the master connection rod
(Fig.5) until the dimension
prescribed in the phase
instructions is obtained.
28
3. Graduación Del Engazador Inferior
(Fig. 3)
Inserte el engazador A en su soporte
posicionandolo en la parte de arriba
con el calibrador 315910-0-00
(incluido con todas las máquinas)
para obtener la dimensión W (vea el
valor en la hoja de fases Pag. 31) el
cual representa la distancia entre el
engazador de atrás y la parte de abajo
de la plancha de la aguja. Asegúrelo
en el nivel de referencia de la pierna
con el tornillo B. Verifique que las
medidas corresponden con aquellas
en las instrucciones de fase (con la
máquina).
Si necesita correcciones, siga las
instrucciones siguientes:
A. Para obtener dimensión "b" (Fig. 4)
mueva el engazador a la extrema
derecha, afloje el tornillo L (Fig. 5)
del sujetador M y mueva la varilla N
(Fig. 5) hasta conseguir la dimensión
determinada en las instrucciones de
fase.

Publicidad

Tabla de contenido
loading

Tabla de contenido