DL2:
receiving RSD radio signal
DL3:
programming enabled
DL4:
gate opening
DL5:
gate closing
PUL1: close mini-pushbutton
PUL2: open mini-pushbutton
T:
earth connection
Operator connections A:
G1
open
G2
close
G3
common, grey
10
General connections
P1 P2 P3
P4 P5 P6
P15 P14 P16
ST1
FT1
ST2
FT2
FCA1
FCC1
ST1
FT1
ST2
FT2
Turning direction: check operation using the mini-pushbuttons
PUL1 (close) and PUL2 (open). If the turning direction of the
operator is not correct, interchange the cables connected in cable
connectors G1 and G2.
SW2 Functions during programming (DIP1=ON)
DIP1=ON: programming enabled (DL3 lights up)
DIP1=ON and DIP2=ON: total open/close programming
DIP1=ON and DIP3=ON: pedestrian open/close programming
DIP1=ON and DIP4=ON: total opening radio code programming
DIP1=ON and DIP6=ON: pedestrian opening radio code programming
P7 P8
P11 P12
P22 P23
G7 G8
G9 G10
Courtesy
24Vac
Lamp.
STOP
LOCK
Light
DEST.
(max. 40W)
VIVO-M101: 230Vac
VIVO-M101M: 125Vac
VIVO-M101: 230Vac
VIVO-M101M: 125Vac
When pressing PUL1 (close), DL5 lights up and the G2 and G3
cable connectors of the operator are enabled.
When pressing PUL2 (open), DL4 lights up and the G1 and G3
cable connectors of the operator are enabled.
G1
G2
G3
N
L
POWER
MOTOR1 (G2-G1-COM)
L
N
G1 G2 G3
LG
VIVO-M101: 230Vac, max 2,300W (resistive)
VIVO-M101M: 125Vac, max 1,250W (resistive)
VIVO-M101:
230Vac/50Hz
VIVO-M101M:
125Vac/60Hz
P175Z