Annual Maintenance; Winterization - MasterCool MCP44 Manual De Instalación Y Funcionamiento

Linea deglada enfriador de ventana
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Annual Maintenance (Con't)
Water Distributor
1.
Inspect the water distribution section to ensure all orifi ces
are clear.
2.
Verify the hose connections are in good order and no
kinks or tears are present.
Water Drain Overfl ow
3.
On the bottom of the cooler, unscrew the plastic nut hold-
ing the overfl ow drain in place. Push the drain up into the
cooler base to allow rapid draining. Check the condition
of the gasket at the bottom of the fi xture. When reinstall-
ing, ensure the standpipe fi xture is secure and there is no
leakage after the reservoir is fi lled.
NOTE: If during usage of the cooler you start notic-
ing low saturation of pads and insuffi cient cooling, or
leakage from the cooler, check the gasket at the base
of the standpipe. This is the most likely cause of leak-
age on this unit.
Optional Water Purge Pump (if installed)
4.
If a purge pump has been installed on the MCP Series,
check that the purge pump and strainer are corro-
sion-free with freely moving parts.
Media Pad Replacement
5.
When the media pads have become encased with miner-
al buildup, broken or damaged, replace them with Gen-
uine Munters GreenGuard Celdek
model MCP44-PAD. You may purchase them on-line at
www.championcooler.com or by calling 1.800. 643.8341.

Winterization

The MCP Series cooler is durable enough to be left installed
during the winter, though a few precautions must be taken to
ensure no water freezes in the unit or lines.
If the temperatures in your area drop well below freezing it
may be wise to remove the water supply line from the
outside faucet.
Draining
1.
Turn off and unplug cooler.
2.
Turn the water supply to the cooler off .
3.
On the bottom of the cooler, unscrew the plastic nut hold-
ing the overfl ow drain in place. Push the drain up into the
cooler base to allow rapid draining.
4.
Remove 4 screws securing the back media guard, lift up
and remove . Access interior of unit.
5.
Soak up any remaining water and ensure all water is
drained from both the water pump and purge pump
(if installed).
6.
Disconnect and drain the water hoses and water
distributor.
7.
Replace the media guard with four screws
replacement pads,
®
10
WATER
DISTRIBUTOR
Covering
1.
An optional weatherproof exterior fi tted cover, model
MCP44-EC is available for purchase on line at www.
championcooler.com, at retail outlets or by calling
1.800.643.8341.
a.
Use the elastic corners and straps to secure the
cover onto the back of the unit.
2.
An optional interior grille cover, model MCP44-IC
(Included with MCP44E) to keep air from entering the
home through the window is available at www.champion-
cooler.com, a retail outlet or by calling 1.800.643.8341.
a.
Use the snap on clips molded into the cover to
secure the cover to the grille.
OPTIONAL
PURGE PUMP
(OWNER INSTALLED)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mcp44cMcp59Mcp serie

Tabla de contenido