Note: Do Not Overfi ll. Fill water to a maximum height of 2 1/2
inches (approximately 1 inch from the top of the bottom pan). If
using a garden hose, the fl oat will need to be adjusted to maintain
this water level. This can be accomplished by bending the fl oat
rod.
Float Body
Float Rod
Maintenance
WARNING:
Before doing any maintenance be sure power is
off and unit is unplugged. This is for your safety.

Annual Maintenance

• Oil bearings. The blower bearings (RMMB14 only) and cooler
motor in this unit should be oiled with a few drops of non-detergent
20/30 weight oil once each year. The motor does not need oil if it
has no oil lines for oiling. Motors that have no oil lines are lifetime
oiled at the factory and require no further oiling for the life of the
unit.
CAUTION:
Do not over oil. Over oiling can cause motor burn
out, due to excessive oil getting into motor winding.
• Change Pads. Pads should be replaced once or twice a season,
depending upon the length of the season. At the beginning and at
mid season a clean pad is more absorbent and effi cient and will
deliver substantially more cool air.
• Check belt and belt tension. This applies only to model RMMB14
which is belt driven. Models MMB10 and RMMB12 have direct
drive motors. Check the belt for any cracks or wear and replace if
Register your product online at www.championcooler.com/index.php/cooler-warranty-registration
This warranty is extended to the original purchaser of an evaporative cooler installed and used under normal conditions. It does not cover damages in-
curred through accident, neglect, or abuse by the owner. We do not authorize any person or representative to assume for us any other or different liability
in connection with this product.
Terms And Conditions Of The Warranty
For Two Years from date of purchase, we will replace any original component provided by Champion Cooler which fails due to any defect in material or
factory workmanship only.
Exclusions From The Warranty
We are not responsible for replacement of cooler pads. These are disposable components and should be replaced periodically. We are not responsible for
any incidental or consequential damage resulting from any malfunction.
We are not responsible for any damage received from the use of water softeners, chemicals, descale material, plastic wrap, or if a motor of a higher horse-
power than what is shown on the serial plate is used in the unit.
We are not responsible for the cost of service calls to diagnose cause of trouble, or labor charge to repair and/or replace parts.
How To Obtain Service Under This Warranty
Contact the Dealer where you purchased the evaporative cooler. If for any reason you are not satisfi ed with the response from the dealer, contact the Cus-
tomer Service Department: Champion Cooler, 5800 Murray Street, Little Rock, Arkansas 72209. 1-800-643-8341. info@championcooler.com.
This limited warranty applies to the original purchaser only.
110522-2
Garden Hose
Adapter
Nut
Washer
Fig. 3
Limited Warranty
necessary. Check the tension on the
belt. A 3 lb. force should defl ect the
belt 3/4 inches (see Fig. 4). Readjust
belt if needed.
• Clean pump. Cleaning the pump
is necessary once a year at start-up.
For your safety, turn unit off and unplug unit and pump. Remove
the pump from the mount slot. Remove the base of the pump (Fig.
5). Clean the pump and turn the impeller to ensure free operation.
Remove the pump spout and check for any blockage. After clean-
ing, reinstall the base onto the
pump. Press fi rmly to make sure
it is secure. Reattach the pump
to the mount in the cooler using
the plastic retainer to ensure that
the pump will not overturn. Do
not forget to replace the spout
and water delivery tube onto the
pump outlet.

Routine Maintenance

• Drain water. It is recommended to drain the water from the
cooler at least once a week. Keeping fresh water in the pan will
help prevent scale and mineral deposits accumulation on the pads.
Always drain all of the water out of the cooler when not in use for
prolonged periods, and particularly at the end of the season.
• Unplug unit from power supply during extended periods of
non-use.
• Cover unit or store inside when not in use.
By following the operating, installation, and maintenance suggestions
as outlined, you can get many years of effi cient and satisfactory
service from your cooler. In the event additional information is
desired, your dealer will be more than glad to assist you in every
possible way.
3 Lb.
3/4 Inches
Fig. 4
Remove
Base
Impeller
Fig. 5