Optional Masterlink Tm Thermostat / Remote; Programming Purge Pump; Optional Plug-In Thermostat Usage - MasterCool MCP Serie Manual De Instalación Y Funcionamiento

Line delgada enfriador de ventana
Ocultar thumbs Ver también para MCP Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPTIONAL INSTALLATIONS / ACCESSORIES (CON'T)
NOTE: When in Purge Set Up Mode, you will not affect the fan speed or main water pump operation.
Once a purge pump has been installed and plugged
into the cooler, the purging cycle can be programmed
from the control panel:
The default setting for the purge pump is 1 minute of
purge every 24 hours. This setting can be changed to
increase interval and duration of purges as needed.
In order to enter the programming
mode of the control panel hold
down the PUMP touch point for
ve (5) seconds.
At this point the Purge Interval
can be set. Four lights on the
left side illuminate. This indicates
one purge every 24 hours.
To change the number of hours between purges,
press PUMP again until the desired schedule is select-
ed. The options for purge interval are 24,12, 8 and 6
hours. The lights decrease by one each time the Pump
button is pressed. Note the legend of intervals listed
below.
4 LIGHTS = EVERY 24 HOURS
3 LIGHTS = EVERY 12 HOURS
2 LIGHTS = EVERY 8 HOURS
1 LIGHT = EVERY 6 HOURS
Optional MasterLink
(Available in 2017)
®
MasterCool
MCP Series coolers
manufactured with the
logo on the control panel will be
compatible with the MasterLink
Thermostat, sold separately. The
thermostat will have a smart phone
app that allows wireless control over
the cooler. This thermostat controls
standard and advanced features,
such as purge pump control and
timer function.
TM
Refer to the MasterLink
owner's manual for instructions on
how to control and program the MCP
Series coolers using this item.

PROGRAMMING PURGE PUMP

PRESS AND
HOLD 5
SECONDS
FAN
HI
M
ED LO
POWER
PU
M
P
HI
POWER
TM
Thermostat
TM
Fan
Pump
Thermostat
Mode
NOTE: Depending on the amount of minerals in
the local water, it may be advantageous to in-
crease the purges to extend the life of the media
and the unit.
After the number of hours in the Purge Interval has
been set, you may select the duration of the purge.
Options are from 1 to 4 minutes that the water will be
PUMP
expelled.
Press the FAN touch point
to enter the Purge Duration
setting feature.
The four lights on the left side
will begin blinking indicating 4
minutes of purging. Press the
PUMP touch point to change
the setting from 4 to 3 minutes,
then 2 or 1 minute duration.
To save and exit the Duration portion of the programming,
press and hold the FAN touch point for 5 seconds.
NOTE: If no touch-point is pressed within 10 sec-
onds, the program will automatically exit the set up
mode and retain previous settings.
FAN
4 LIGHTS BLINKING = 4 MINUTES
3 LIGHTS BLINKING = 3 MINUTES
M
ED LO
2 LIGHTS BLINKING = 2 MINUTES
1 LIGHT BLINKING = 1 MINUTE
PU
M
P

Optional Plug-In Thermostat Usage

The MCP Series also can be con-
trolled by a plug-in programmable
thermostat, such as the LUX brand
WIN 100. These thermostats
are locally available, and enable
precise timing and temperature
control via an electronic thermostat
that plugs into a 110 volt outlet. To
use such a device with the MCP
series cooler, follow the instructions
for the speci c thermostat and plug
the cooler into the outlet on the
thermostat.
Timer
NOTE: Illustration is for reference
only, models and features vary by
model and manufacturer.
9
FAN
PRESS TO
SET PURGE
DURATION
FAN
HI
M
ED LO
POWER
PU
M
P
FAN
HI
M
ED LO
POWER
PU
M
P

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Mcp44Mcp44eMcp59

Tabla de contenido