Controller For The Air Source Heat Pump Water Heater
③ After the circular sterilization function is set, the water heater can still precisely
calculate the day interval for sterilization accumulatively and the circular
sterilization function can still work in the case of short-term power failure. If the
time point for sterilization is within the power failure duration, sterilization will be
made up once power is provided again. In addition, the day interval for
sterilization will be recalculated accumulatively based on this sterilization and
next sterilization will be calculated accordingly.
④ Ensure that there is no long-term power failure; otherwise, the clock of the water
heater will malfunction and the STERILIZE function will not work properly.
⑤ Under the E-HEATER mode, the STERILIZE function is unavailable.

6.6.5 VACATION

In the On state, press the FUNCTION button to enter the function selection
interface. When the VACATION function is selected, the corresponding icon blinks. At
the same time, the preset number of vacation days is displayed at the clock position, as
shown in the following figure.
During this period, the following operations can be performed:
1) Press ▲ or ▼ to start or cancel the VACATION function. After this function is
started, the VACATION icon will be displayed without blinking and the water heater
runs based on the preset number of vacation days; If this function is canceled, the
VACATION icon will not be displayed. If no operation is performed within 5 seconds, it
will be regarded that this function is not required.