Electrical Requirements; Recommended Grounding Method - Whirlpool ACQ052PK0 Manual De Uso Y Cuidado E Instrucciones De Instalación

Acondicionador de aire
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical requirements

WARNING
!
Electrical Shock Hazard
Plug into a grounded 3-prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
In the U.S. only: If codes permit and a separate
ground wire is used, it is recommended that a
qualified electrician determine that the ground path
is adequate.
Check with a qualified electrician if you are not sure air
conditioner is grounded.
A three-wire, single-phase, 60-Hz, AC-only, electrical
supply is required on a separate circuit. See model and
serial label for circuit amperage required for your
specific model.
A time delay fuse or circuit breaker is required . Use
copper wire only.
The model and serial label is located behind the front
panel on the cabinet. This label lists the BTU capacity,
amperage, voltage and refrigerant charge requirements.
12

Recommended grounding method

For your personal safety, this air conditioner must be
grounded. This air conditioner is equipped with a power
supply cord with a 3-prong grounding plug. To minimize
possible electrical shock hazard, the cord must be
plugged into a mating 3-prong grounding-type outlet,
grounded in accordance with all local codes and
ordinances. If a mating 3-prong grounding-type outlet is
not available, it is the consumer's responsibility to have
a properly grounded, 3-prong outlet installed by a
licensed installer.
It is the customer's responsibility:
• To contact a qualified electrical installer.
• To assure that the electrical installation is adequate
and in conformance with National Electrical Code,
ANSI/NFPA 70 — latest edition,* and all local codes
and ordinances.
Copies of the standards listed may be obtained from:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
Power supply cord and receptacle
.
• 115 volt
(103.5 min. - 126.5 max.)
• 0-12 amperes
• 15-amp time-delay fuse or
circuit breaker
• 14 gauge copper wiring

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Acq062pk0

Tabla de contenido