Operating instructions
Electronic display counter
CODIX 52U

1.1 Safety instructions and warnings

Only use this display
– in a way according to its intended
!
purpose
– if its technical condition is perfect
– adhering to the operating
instructions and the general
safety instructions.

1.2 General safety instructions

1. Before carrying out any installation or mainte-
nance work, make sure that the power supply
of the digital display is switched off.
2. Only use this digital display in a way according
to its intended purpose: If its technical condi-
tion is perfect. Adhering to the operating
instructions and the general safety instructions.
3. Adhere to country or user specific regulations.
4. The digital display is not intended for use in
areas with risks of explosion and in the branch-
es excluded by the standard EN 61010 Part 1.
5. The digital display shall only operated if it has
been correctly mounted in a panel, in accor-
dance with the chapter "Main technical features".

1.3 Use according to the intended purpose

The digital display may be used only as a panel-
mounted device. Applications of this product may
be found in industrial processes and controls, in
manufacturing lines for the metal, wood, plastics,
paper, glass, textile and other processing indus-
tries. Over-voltages at the terminals of the digital
display must be kept within the limits in Category II
If the digital display is used to monitor machines
or processes in which, in case of a failure of the
device or an error made by the operator, there
might be risks of damaging the machine or caus-
ing accidents to the operators, it is your responsi-
bility to take appropriate safety measures.
1.4 Description
CODIX 52U is a multipurpose device. Depend-
ing on the programmed basic function, the
device operates like
• an electronic totaliser and frequency meter
(see page 2)
• an electronic display counter with
2 totalising ranges (see page 4)
• an electronic totaliser and time meter
(see page 6)
• an electronic time meter with 2 time ranges
(see page 9)
2. Setting of the operating parameters
a. Press both front side keys keys and switch
on the supply voltage or, if the supply voltage
is already on, press both keys simultaneously
during 5 s.
b. The display shows
c. After releasing the keys, the display shows
c1. Hold the left key pressed and press the right
key to leave the programming operation.
c2. Press the right key to switch to
d. Hold the left key pressed and press the right
key to switch to the first parameter.
e. After releasing the keys, the display alternates
between the menu title and the current menu
item setting. After pressing any key, only the
menu item setting is displayed.
f. Pressing the right key, the menu item setting
will be switched to the next value. If figures
are to be input (e.g. when setting the scaling
factor), select first the decade using the left
key, and then set the value using the right key.