TROUBLESHOOTING GUIDE

Trouble
Digital display not illuminated.
Fan not operating (digital display
is illuminated).
Fan running continuously.
Poor evaporation of water.
Bottle empties completely.
Bottle continues to empty after
complete filling.
Bottle not emptying
CF message does not appear
even when filter is dirty or
humidifier performance is clearly
reduced.
Fan operating slower than speed
registered on digital display.
Humidifier not shutting off during
DRY OUT mode.
Controls are unresponsive or CL is
displayed
Display flashes "20"
Display flashes "—"
Probable Cause
• No Power.
• Power button has not been
depressed.
• ROOM humidity level is not
3 % or more below SET
humidity level.
• SET humidity level is 65%.
• ROOM humidity level has
not reached 1% or more
above SET humidity level.
• CF (Check Filter) message
flashing.
• This is normal for initial filling.
• Air is entering water bottle.
• Base full of water.
• A loss of power has caused the
CF (check filter) message to
prematurely reset.
• Humidifier is in DRY OUT mode.
• Filter not dry.
CONTROL LOCK (CL) feature has
been activated.
• ROOM Humidity is
lower than 20%.
• Unit initiating.
• Room humidity is over 90%.
11
Remedy
• Check 120 volt power source.
• Press power button once to turn on.
• Raise SET humidity level if desired.
• A SET humidity percentage of
65% operates fan continuously.
Adjust SET level between 25% - 60%.
• Continue to run until desired
humidity level is achieved. This
may take up to 48 hours initially.
• Change to a fresh new filter.
NOTE: Local water varies from area to
area and under certain conditions mineral
will build up more rapidly in the filter.
• Refill bottle for maximum run time.
• Ensure fill cap is tight with no
interfering debris.
• Check for leak in water bottle.
• The base will hold the contents of
water bottle (1.9 gallons/ 7.2L).
Continue to run humidifier to deplete
water from base.
• Replace filter.
• Humidifier automatically
switches fan speed to ULTRA
QUIET when DRY OUT mode
message is displayed.
• During DRY OUT mode the
humidifier will continue to run
on ULTRA QUIET speed as
required for a 2 hour period
Hold power button down for 5 seconds.
Control Lock function will deactivate.
• Will read actual humidity when level
comes up to 25%.
• Room humidity will display after initiation
is complete.
• Will remain until humidity drops below
90%.