3.4 Current sensor
Fit the current sensor to the plus (+) cable to the anchor windlass motor. Use tape or ty-
raps
®
for this. Fit the current sensor as shown. Make sure that it is fitted in the correct direc-
tion.
Position the current sensor at least 1 metre from a magnetic field.
Do not position the current sensor in the vicinity of other electric wires carrying a high cur-
rent.
3.5 Connections to instrument
10-pole connector
No.
Signal
1
+ battery
2
– battery
3
– battery
4
5
current sensor
6
command 'UP'
7
command 'DOWN'
8
9
10
chain sensor
Control panel / chain counter CCM
8
7
9
6
10
1
5
2
4
3
060123.01
ENGLISH
19