Appendix 1: Technical data
Model
Nominal output
Flue connection (diameter)
Weight
Recommended fuel
Fuel property, max. length
Mass flow of flue gasses
Flue gas temperature measured in the
measurement section
Temperature measured at appliance
exit
Minimum draught
CO emission (13%O
)
2
NOx emission (13% O
2
CnHm emission (13%O
Particulate emission
Particulate emission in accordance
with NS3058-NS3059
Efficiency
24
Sense
100/103/113/
200/203
4.9 kW
150 mm
105 kg - 125 kg
Wood
33 cm
4.5 g/s
247 ℃
317 °C
12 Pa
0.18 %
)
81 mg/Nm³
)
173 mg/Nm³
2
27 mg/Nm³
2.87 g/kg
79.5%
Sense
Sense
100/103/113/
300/303/
200/203
400/403
7.0 kW
9.0 kW
150 mm
150 mm
105 kg - 125 kg
150 kg - 180 kg
Wood
Wood
33 cm
40 cm
5.1 g/s
7.3 g/s
274 °C
274 °C
351 °C
352 °C
12 Pa
12 Pa
0.07 %
0.08 %
89 mg/Nm³
75 mg/Nm³
76 mg/Nm³
69 mg/Nm³
25 mg/Nm³
-
2.87 g/kg
-
80 %
80 %
Subject to change because of technical improvements