WIRING
Installation work and electrical wiring must be
done by a qualified person(s) in accordance
with all applicable codes and standards, includ-
ing fire-rated construction codes and standards.
1. Connect power cable to housing. Attach electri-
cal power cable to housing using appropriate
connector. Allow 6" of wire inside housing.
Secure ground wire to housing with grounding
clip, as shown.
2. Wi re t h e h e a te r
assembly. Connect
wires from heater
assembly to power
cable wires. Follow
wiring diagram.
If heater is wired
direct, use the built-
in thermostat for
temperature control.
GROUNDING CLIP DETAIL
OPTIONAL WIRING
CONVERSIONS
When using a separate wall control, simply turn
the heater's built-in thermostat to its highest set-
ting. There is no need to disconnect the built-in
thermostat:
a) Turn built-in thermostat to highest setting.
b) Remove knob.
c) Fasten security cover to grille.
LINE-VOLTAGE THERMOSTAT
CUT WIRE
REMOTE
THERMOSTAT
If wall-mounted control is desired, use the Model
86W Line-Voltage Thermostat. Purchase thermo-
stat separately.
Cut blue wire. Strip ½" of insulation from each
end. Connect wires from wall control to each
stripped wire.
If wall-mounted control is desired, use a trans-
fomer/relay with an appropriate low-voltage
thermostat (purchase separately). Follow the
mounting and wiring instructions packed with
the controls.