4.5 DC protector

The DC protector turns to "OFF" (2) automatically when electric device being
connected to the generator is operating and current above the rated flows. To use
this equipment again, turn on DC protector by pressing its button to "ON" (1)
(1) "ON"
Direct current is output.
(2) "OFF"
Direct current is not output.
• Reduce the load of the connected electric device below the specified
rated output of the generator if the DC protector turns off. If the DC
protector turns off again, stop using the device immediately and consult
our company authorized dealer.

4.6 Engine smart control (ESC)

(1) "ON"
When the ESC switch is turned to "ON", the economy control unit
controls the engine speed according to the connected load. This results in
greatly reduced noise.
(2) "OFF"
When the ESC switch is turned to"OFF", the engine runs at the rated
r/min(4500r/min) regardless of whether is a load connected or not.
TIP: The ESC must be turned to"OFF"when using electric devices that require
a large starting current, such as a compressor of a submergible pump.