Use part number MFR-DC10 for replacement chamber cartridge, flux filter and in-line fume
filter.
To ensure good vacuum check all filters, hoses, coil assembly seal and desolder cartridge for
blockages.
LED Indications and Meaning
Auto-Sleep and Auto Off Functions
To prolong tip life, MFR systems with a soldering hand-piece (MFR-H1-SC2, MFR-H2-ST2)
include an "Auto-Sleep Workstand" (WS1). When the hand-piece is placed into the workstand,
the "Auto-Sleep Workstand" immediately reduces power to the hand-piece.
All MFR systems have an "Auto Off" Function. The "Auto Off" Function will be engaged when
the hand-piece has been idle in the sleep stand for a period of two hours. The channel LED
indicator light will go from green to Off. The "Auto Off" Function can be reset by cycling the
power switch.
SmartHeat® & Calibration
SmartHeat® technology establishes and retains heater idle temperature by virtue of Curie effect
inside the heater core. This phenomenon occurs at the atomic level and consequently idle
temperature cannot shift over time nor can it be altered by the operator. Accordingly the system
requires absolutely no calibration. Contact us at support@okinternational.com
A/C Power LED
· Green----Power On
· Red------ A/C Input Ground Fault
· Off-------- Power Off
Channel LED
· Green-------------- On / Ready
· Red----------------- Ground continuity fault,
· Off------------------ Channel not
7
No tip cartridge,
No power
selected or auto off