Testing The Detector - DAITEM SH151AX 3 Manual De Instalación

Detector de humo y de calor radio sistema, 10 años de autonomía
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GB
To programme a detector as a relay:
1. Press Cfg1. After 4 s, the red LED flashes. Keep holding the button down.
2. After 10 s, the flashing speeds up or slows down:
- if the flashing speeds up, the relay function has been activated,
- if the flashing slows down, the relay function is still deactivated.
3. Release the button and press briefly on Cfg1 to exit the programming mode.
Putting a detector back into its factory configuration
Upon the back into factory configuration, the interconnection between the detectors will be deleted.
1. Press 2 times on the Cfg1 key.The red LED flashes.
2. Keep holding on the Cfg1 key until the red LED light up steadily. Release the button.
3. Briefly press Cfg1 to exit the programming mode.

3. Testing the detector

IMPORTANT
• The detectors must be installed before test.
• Before a smoke detector test, it is advisable to first let your neighbours know and take the
necessary precautions to prevent hearing disorders.
• Never use a naked flame to test the detector.
• The test must be performed at least once a month and notably after a prolonged absence.
Press the detector test button until you hear the 2
Rapid flashing
Emergency halo lighting
Sounding for 1 sec. (75 dB (A) at 1m)
followed by a 1 sec. pause
Press the test button again to stop the integrated sounding.
Detector activated
beep and then release it.
nd
Other interconnected detectors
Emergency halo lighting for 250 ms
followed by a 1.75 sec. pause
Sounding for 250 ms (75 dB (A) at 1m)
followed by a 1.75 sec. pause
112
-