4.3 Fault indications

In order not to wake you up, alarms resulting from mains supply problems or dirty sensors are shut
down during the night. Any errors are corrected after daybreak within 10 minutes i.e. 8 hours after the
event.
4.3.1 Power fault
Detector at the source
of the fault indication
2 flashes every 5 sec.
2 rapid beeps every 60 sec.
If the audible power fault indication occurs at an inconvenient time, it can be postponed for 8 hours
over a maximum duration of 7 days by pressing the test button until you hear the first beep.
IMPORTANT: when the power fault occurs, the detector continues to operate perfectly for 30 days.
It is advisable to replace the detector as soon as possible.
If the detector is associated with a control panel, the panel provides vocal notification following a
system command: "Beep, power fault, detector n° X".
4.3.2 Detection head faulty or dirty
Detector at the source
of the fault indication
8 flashes every 8 sec.
8 rapid beeps every 60 sec.
If the audible detection head fault indication occurs at an inconvenient time, it can be postponed for
8 hours over a maximum duration of 7 days by pressing the test button until you hear the first beep.
You have these 7 days to clean the detector.
Other interconnected detectors
1 flash every 10 seconds
2 rapid beeps every 60 sec.
Other interconnected detectors
1 flash every 10 seconds
8 rapid beeps every 60 sec.
115