ATTENTION
Insert the plug in a socket for models with a capacity < 4.5 kW.
Connect the power cable directly to the mains for models with a capacity > 4.5 kW Do not use a
plug and socket. The high current can damage the pins of the plug and the socket and cause fire.
Outdoor unit:
To the indoor unit

11.2 Connecting the power cables for the S 39xx models.

a.
Connect the cable of the indoor unit first.
b.
The connecting cable for the connection of the indoor unit with the outdoor unit has to be a type
H07RN-F, 2.5 mm² cable.
c.
To connect the cable to the terminal block of the indoor unit: Remove the front panel and the cover
of the terminal block. The terminal block is located at the right side of the indoor unit. Picture 19.
Front panel
Picture 19
d.
The cable can be guided to the terminal block via the rear of the indoor unit in the same way as the
already placed power cable.
e.
Connect the wires to the terminal block. Refer to Fig. 20 for the correct position.
Picture 20
f.
Now connect the cable of the outdoor unit. Remove the cover of the terminal block of the outdoor
unit.
4
58
Outdoor unit:
Secure the cable with a cable clamp
Cover plate
to the outdoor unit