6.2.2 External power supply
1
6
1
J1, J2
2
J3, J4
Fig. 5
Power supply
On an AIDA-compliant eBOX, the logic circuit is externally powered via the X3 port (5) in order to avoid
any bus communication failure if the internal power supply fails.
When using an external power supply, configure the following jumper settings on the main PCB (4), always
retaining the order shown:
1 Set jumper (1) to off (top position), jumper (2) to on (left position) and jumper (3) to on (top position).
2 Switch on the eBOX at the main switch Q1 (6).
3 Connect the AIDA power connector to the X3 port (5).
2
5
3
J5, J6
4
Main PCB
6 Putting into operation
3
4
5
US1/US2 port X3
6
Main switch Q1