Installation instruction
30
all-pole disconnection device with a minimum of
a 3 mm contact gap. If the UV shall be connected
with a plug make sure that it is accessible.
> The UV must be protected on site with a maxi-
mum fuse of 16 A.
> The UV is fitted with a cable approx. 2 m in
length without plug.
> If the power cord shall be changed, the quality of
the cord must be at least H05 RN-F 3x1,5 mm2
> In case the power cable must be changed use a
cable that matches your local standards.
The exchange of the power cable may only be
carried out by the manufacturer, his service
agents or similar qualified personal