Bosch TPA 200 Manual Original página 25

Aparato de diagnóstico para sensores de la presión de los neumáticos
Ocultar thumbs Ver también para TPA 200:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
5.6
Repair
This function enables you to perform a test of
the sensors again after a repair (e.g. a sensor
has been changed).
1. Switch on the TPA 200.
Main Menu
is displayed.
Check
is displayed.
2. Select "Repair" with
with
.
Vehicle >New Vehicle
(not in the case of operation sequence
"None").
i
If tests on vehicles have already been
performed and saved, and if the operation
sequence is set for "Job code", "Registration"
or "Model Year", these vehicles can be se-
lected again and tested.
Select Make
3. Select " Select Make" with
confirm with
.
Select Model
4. Select " Select Model" with
confirm with
.
Select Year
5. Select " Select Year" with
confirm with
.
i
In the case of operation sequence
"Job code", the order number of the vehicle
to be tested can be entered before the
sensor test with
, and in the case of operation sequence
Registration the license number of the ve-
hicle to be tested can also be entered.
Front Left >Read Sensor
played.
Robert Bosch GmbH
or
and confirm
is displayed
is displayed.
or
and
is displayed.
or
and
is displayed.
or
and
or
and confirm with
is dis-
Operation | TPA 200 | 25
The following menu items can be selected:
Menu item
Description
>Read Sensor
The sensor is read.
>Req. Repair
Only select, if the sensor is visi-
bly faulty. A message about repair is
made in the test protocol. The sensor
is not read.
>Skip Wheel
The selected sensor is not read.
>Cancel Audit
Return to the main menu. No data is
saved.
6. Hold the TPA 200 close to the tire valve.
Front Left >Read Sensor
played.
7. Confirm with
.
 The sensor is read and then displays the
sensor data, e.g.
2.5bar Bat:OK
ID:00001A635
i
Repeat the search, if the sensor could not
be read.
8. Confirm with
.
9. Read the sensors of all the wheels in accor-
dance with the given sequence.
10. Confirm with
.
Vehicle Data >Save
The following menu items can be selected:
Menu item
Description
Vehicle Data
The measurement data is saved.
>Save
Vehicle Data
The individual sensors can be marked
>Edit
with
, showing whether they should
be repaired. The message about re-
pair is then made in the test protocol.
Order numbers or license numbers
can also be edited.
Vehicle Data
The measurement data is not saved.
>Exit
Vehicle Data >Save
 Confirm with
"
The measurement data of the sensors is saved.
" Main Menu
is displayed.
1 689 989 200
en
is dis-
is displayed.
is displayed.
.
|
2014-05-08

Publicidad

Tabla de contenido
loading

Tabla de contenido