6 | English
When there is no battery connected, the continuous light of
the battery charge level indicator (4) indicates that the
mains plug is plugged into the mains socket and that the
charger is ready to be used.
Continuously illuminated red battery charge level
indicator (3)
The continuous light of the red battery charge
level indicator (3) shows that the temperature
of the battery is outside of the permitted char-
ging temperature range, see section "Technical
data". The charging process begins as soon as the permitted
temperature range has been reached.
Flashing red battery charge level indicator (3)
The flashing light of the red battery charge
level indicator (3) signals that the charging
process has been interrupted by a different
fault, see section "Errors – causes and correct-
ive measures".
Errors – causes and corrective measures
Cause
Corrective measures
Red battery charge level indicator (3) is flashing
Charging not possible
The battery is not connected
Connect battery to charger
(correctly)
correctly
Battery contacts are dirty
Clean battery contacts; e.g.
by connecting and discon-
necting the battery several
times. Replace battery if ne-
cessary
Battery defective
Replace battery
Green battery charge level indicator (4)/Red battery
charge level indicator (3) is not illuminated
Mains plug of the charger is
Insert the mains plug into the
not (correctly) plugged in
mains socket (completely)
Socket outlet, mains cable or
Check mains voltage, have
charger defective
charger checked if necessary
by an authorised after-sales
service centre for Bosch
power tools
Practical advice
When the charger is used continuously, or for several con-
secutive charge cycles without interruption, the charger may
heat up. This is, however, harmless and does not indicate
that the charger has a technical defect.
A significantly reduced operating time after charging indic-
ates that the battery has deteriorated and must be replaced.
1 609 92A 4Z4 | (12.02.2019)
Maintenance and Service
Maintenance and cleaning
In order to avoid safety hazards, if the power supply cord
needs to be replaced, this must be done by Bosch or by an
after-sales service centre that is authorised to repair Bosch
power tools.
After-Sales Service and Application Service
Our after-sales service can answer questions concerning
product maintenance and repair, as well as spare parts. You
can find exploded drawings and information on spare parts
at: www.bosch-pt.com
The Bosch product use advice team will be happy to help you
with any questions about our products and their accessor-
ies.
www.powertool-portal.de, the internet portal for trades-
people and DIY enthusiasts.
In all correspondence and spare parts orders, please always
include the 10‑digit article number given on the type plate of
the product.
Cambodia
Robert Bosch (Cambodia) Co., Ltd
Unit 8BC, GT Tower, 08th Floor, Street 169,
Czechoslovakia Blvd, Sangkat Veal Vong
Khan 7 Makara, Phnom Penh
VAT TIN: 100 169 511
Tel.: +855 23 900 685
Tel.: +855 23 900 660
www.bosch.com.kh
People's Republic of China
China Mainland
Bosch Power Tool (China) Co. Ltd.
Bosch Service Center
567, Bin Kang Road
Bin Kang District
Hangzhou, Zhejiang Province
China 310052
Tel.: (0571) 8887 5566 / 5588
Fax: (0571) 8887 6688 x 5566# / 5588#
E-mail: bsc.hz@cn.bosch.com
www.bosch-pt.com.cn
HK and Macau Special Administrative Regions
Robert Bosch Co. Ltd.
21st Floor, 625 King's Road
North Point, Hong Kong
Customer Service Hotline: +852 2101 0235
Fax: +852 2590 9762
E-mail: info@hk.bosch.com
www.bosch-pt.com.hk
India
Bosch Service Center
69, Habibullah Road, (next to PSBB School), T. Nagar
Chennai–600077
Phone: (044) 64561816
Bosch Service Center Rishyamook
85A, Panchkuin Road
Bosch Power Tools