Tabla De Contenido; Identification Of Part; Safety Information; Important - Desa Master B 130 Manual Del Proprietário

Tabla de contenido

Publicidad

CONTENTS

IDENTIFICATION OF PART

The hot air generators is designed in compliance with current
safety, performance and life standards, is fi tted with safety
devices confi gured to guarantee continuous operation, minimize
noise and are manufactured in carefully selected materials that
ensure maximum reliability.

SAFETY INFORMATION

! WARNING !
IMPORTANT: Read the manual carefully before attemp-
ting to assemble,switch on or service this heater. The use
of the heater may cause serious or fatal injuries resulting
from burns, fi re, explosion, electrical discharge or carbon
monoxide poisoning.
DANGER: CARBON MONOXIDE POISONING CAN BE
FATAL.
Carbon monoxide poisoning The fi rst symptoms of carbon
monoxide poisoning are similar to those of fl u, with headache,
dizziness and/or nausea.These symptoms may be caused by
the defective functioning of the heater. Go outside into the open
air immediately! Have the heater repaired. Some people feel
the effects of carbon monoxide to a greater extent, especially
pregnant women, those suffering from anaemia, cardiac or lung
conditions, those who are drunk and anyone at a high altitude.
Ensure that you have read and understood all the warnings.
Keep this manual for future reference - it is a guide to the safe
and correct functioning of the heater.
• Use only fuel diesel / kerosene in order to avoid the risk of fi re
or explosion. Never use petrol, naphtha, paint solvents, alcohol
or other highly infl ammable combustibles.
• Fuelling:
a) The individual responsible for fuelling the heater must have
the relevant competence and be completely familiar with the
manufacturer's instructions and with current norms concer-
ning the safe fuelling of the heaters.
b) Only use the type of fuel expressly specifi ed on the identifi ca-
tion label of the heater.
c) Before adding fuel, extinguish all fl ames, including the pilot
light, and wait until the heater has cooled down.
d) While adding fuel, inspect all the fuel lines and joins to make
sure there are no leaks.
Any leak whatsoever must be repaired before switching on
the heater.
e) In no circumstances must more than one day's supply of
fuel be stored in the same building in proximity to the heater.
Fuel storage tanks must be kept in a separate location.
f) All fuel tanks must be kept at a minimum distance from hea-
ters, oxyacetylene torches, welding equipment etc. (with the
exception of the fuel tank incorporated into the heater) fol-
lowing regulations.
g) Wherever possible, fuel should be stored in a place where
the fl oor does not allow fuel to seep through and drip onto live
fl ames beneath, which might cause fi re.
h) Fuel must be stored in compliance with current norms.
• Never use the heater anywhere where petrol, paint solvents or
other highly infl ammable vapours are present.
• While using the heater, follow all local ordinances and current
norms.
• Heaters used in the proximity of tarpaulins, curtains or other co-
vering materials must be situated at a safe distance following
regulations. It is also recommended to use fi reproof materials.
These materials should be fi xed safely so as to ensure that
they do not catch fi re and are not blown by the wind.
• Only use in locations where there are no infl ammable fumes or
high concentrations of dust.
• Use only in well-vented areas. Before using heater, provide at
least a 2800 square cm (three-square-foot) opening of fresh,
outside air for each 30 kw (100.000 Btu/Hr) of rating.
• Power the heater only with electric power that has the voltage,
frequency and number of phases specifi ed on the identifi cation
label.
• Minimum heater clearances from combustibles: Outlet: 250 cm
(8 Ft.) Sides, Top, and Rear: 125 cm (4 Ft.).
• In order to avoid the risk of fi re, make sure the heater is on a
fi rm, fl at surface when it is being used or is hot.
• When moving or storing the heater, keep it level to avoid fuel
loss.
• Keep children and animals away from the heater.
• Disconnect the heater from the mains supply when not in use.
• When controlled by a thermostat, the heater may come on at
any moment.
• Never use the heater in frequently used rooms or in be-
drooms.
• Never obstruct the air intake (rear end) or the air output (front
end) of the heater.
• When the heater is hot, connected to the mains supply or in
use, it must never be moved, handled, fi lled up with fuel or
serviced in any way.
• Never attach duct work to front or rear of heater.
1
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Master b 180

Tabla de contenido