The absorption period also ends when the output current of the solar charger drops to less
than 2 Amps, not because of low solar array output but because the battery is fully charged
(tail current cut off).
This algorithm prevents over charge of the battery due to daily absorption charging when the
system operates without load or with a small load.
8.3 Connectivity
Several parameters can be customized (VE.Direct to USB cable, ASS030530000, and a
computer needed). See the data communication white paper on our website.
The required software can be downloaded from
http://www.victronenergy.nl/support-and-downloads/software/
The charge controller can be connected the to a Color Control panel, BPP000300100R, with a
VE.Direct to VE.Direct cable.