Application
Wash basin wall fitting suitable for:
• Direct connection to cold water supply
• Connection to outlet of upstream mixed water supply
Safety notes
• Installation is only possible in frost-free rooms.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification.
Technical data
• Flow pressure
min. 0.5 bar - recommended 1 - 5 bar
• Operating pressure
• Test pressure
If static pressure exceeds 5 bar, a pressure-reducing valve
must be fitted.
• Flow rate at 3 bar flow pressure:
• Temperature
Water supply:
Recommended (energy saving):
• Voltage supply:
6V lithium battery type CR-P2
• Automatic safety shut-off
(factory setting):
• Run-on time (factory setting):
• Reception range with Kodak Gray Card, grey side,
8 x 10", landscape, 5cm below the spout
(factory setting):
• Type of fitting protection:
General functions
• Thermal disinfection:
• Remaining battery capacity:
Programme 1 functions (factory setting)
• Cleaning mode:
• Automatic flush:
• Thermal disinfection time:
Further pre-set programmes can be selected via the sensor
system.
Additional instructions regarding programme overview,
programme selection and activation of the functions can
be downloaded under www.grohe.com/tpi/euroeco-ce.
Special accessories
Further settings and special functions are available via the
infrared remote control (Prod. no. 36 206).
3
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
Flush pipes thoroughly before and after installation
(observe EN 806).
max. 10 bar
16 bar
1. Removing fitting, see fold-out page I, Figs. [1] and [2].
2. Screw on solenoid valve housing (A) and align vertically,
see Fig.[3]. Observe correct installation depth.
3. Connect plug-in connector between solenoid valve (B)
approx. 6 l/min
and electronics, see Fig. [4].
4. Insert plug-in connector behind tabs (C).
max. 70 °C
5. Connect plug-in connector between electronics and
60 °C
battery housing (D), see fold-out page II, Fig. [5].
6. Insert battery hosing (D) into fitting housing (E).
7. Secure battery housing to fitting housing (E) using rubber
60 s
band (F), see Fig. [6].
1 s
8. Push fitting housing (E) onto solenoid valve housing (A)
and press against the wall.
9. Fasten fitting housing (E) with screw (G), see Fig. [7].
approx. 14cm
10. Ensure that fitting is flush against the wall (visual check).
IP 59K
If necessary, detach fitting from wall and align fitting by
means of adjusting screw (H) as shown in Fig. [8].
11. Open water supply and check connections for
activatable
watertightness.
readable
12. Remove rubber band (F), see Fig. [9].
activatable
Operation
deactivated
The infrared electronics emit invisible, pulsed light.
3.5 min
The sensor system is adjusted so that water flow is
initiated when the hands approach the vicinity of the spout.
When the hands are withdrawn from the vicinity of the
spout, water flow is stopped after 1 s (factory setting).
The range of the sensor system is dependent upon the
reflective properties of the detected object.
Automatic safety shut-off
After 60 s (factory setting) of continuous detection of an object,