Preparing Your Fronius Ig / Ig Plus For Commissioning; General Remarks; Installing The Display Card In Fronius Ig / Ig Plus - Fronius IG 400 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Preparing your Fronius IG / IG Plus for commissioning

General remarks

Important! The mounting bracket is part of the antenna. Only fit the antenna to the
mounting bracket supplied with the antenna.
Installing the
To install a plug-in card:
display card in
1.
Fronius IG / IG
2.
Plus
3.
4.
5.
6.
WARNING! Mains voltage can cause fatal injuries. The connection area
should only ever be opened by an authorised electrical engineer, and only
when the power is disconnected.
WARNING! Mains voltage and DC voltage from the solar modules can cause
fatal injuries. Plug-in cards must not be installed unless the Fronius IG / IG Plus
-
has been disconnected on the mains (AC) side.
-
has been disconnected on the solar module side (DC side)
NOTE! In the case of systems with several inverters, the antennae must be at
least 0.5 m (20 in.) apart so that communication with the personal display is not
disrupted. For an optimum range, we recommend a distance of 1 m (39 in.)
Put Fronius IG / Ig Plus into „Standby" mode
Disconnect Fronius IG / IG Plus on both the AC and DC sides
Open connection area or remove housing cover. See chapter entitled „Opening the
housing" in your Fronius IG / IG Plus operating instructions
Depending on the model:
-
Slide display unit to the left and pull forwards to remove
-
Unplug the ribbon cable of the display unit from the control board
NOTE! Risk of damage to the plug-in card. Be sure to follow the general ESD
regulations when fitting plug-in cards.
Undo fastening screw (2) for an unoccupied slot and remove cover from slot
(2)
5

Hide quick links:

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Ig 500

Tabla de contenido