LIMIT SWITCHES AND OBSTACLE DETECTION
(Only motors with mechanical limit switches)
After having memorized the first remote control and properly assigned the rotation
direction, the control unit is ready for operation.
Run two complete ascent and descent cycles with the A and C buttons on the
remote control to memorise the operating times and enable obstacle detection.
In the event an obstacle is detected, the control unit will perform a safety movement
in reverse equal to about ¼ of the blind travel.
CLOSING FORCE ADJUSTMENT
(Only motors with mechanical limit switches)
+
B
C
In the event that safety and anti-burglary devices
have been installed such as lockdown hangers,
this system ensures that the blinds remain
completely closed without the slats undergoing
excessive compression or requiring excessive force
to open in the event there is a limit stop installed
with fixed/removable safety lugs in the guides.
The control unit has been set in the factory to a
predetermined closing force setting, equal to 20%
of the rated torque. With the remote control it is
possible to change this setting, reducing it to 10%, or increasing it to 40%, depen-
ding on the desired result. Near the end stop positions a short slackening movement
is performed to reduce the force and pressure put on the bars.
TM2 X R COMPACT
A
29
A
40%
B
20%
C
10%
2 sec
A4518_6H81_Rev.A