Setting The First Remote Control And Setting The Rotation Direction Of The Motor - FAAC TM2 X R COMPACT Manual Del Usario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 75
SETTING THE FIRST REMOTE CONTROL AND SETTING
THE ROTATION DIRECTION OF THE MOTOR
This operation can only be performed when the control unit is new, or after a total
delete of the memory.
During this step, power up only one control unit at time!
T1: First remote control to be set
+
A
B
T1
After the last confirmation movement, the motor starts a series of UP and DOWN
movements: the first lasts 2 seconds, the next ones go to the limit switch positions
(motors with mechanical limit switches) or long movements - max 10 seconds
(motors with electronic limit switches). To properly associate the UP and DOWN
buttons, press the button corresponding to the motor movement for one second
as indicated below:
?
Every time you connect the power supply to the control unit, you have 3 hours
to store the first remote control. After this time, the ability to store the remote
control is disabled. To reset the timer of the function you have to disconnect
and reconnect the power supply to the control unit.
TM2 X R COMPACT
AUTOMATIC DISABLING OF THE FIRST
REMOTE CONTROL SETTING FUNCTION
B
T1
A
C
T1 (1 sec)
28
B
T1 (2 sec)
The motor stops: the UP
and DOWN buttons are
now properly associated.
A4518_6H81_Rev.A

Publicidad

Tabla de contenido
loading

Tabla de contenido