SHORT-TERM SETTING OF A REMOTE CONTROL AND SETTING
THE ROTATION DIRECTION OF THE MOTOR
This function makes it possible to store a remote control temporarily, for example,
with the purpose of setting the limit switches during assembly in the factory. A later
final saving of the remote control will be possible using the appropriate command
sequence (see: "SETTING THE FIRST REMOTE CONTROL"). The operations described
below can be carried out only when the control unit has just come out of the factory
or after a full memory clearing (see: "FULL MEMORY CLEARING"). The control unit
makes the following operations possible only within the time limits described in
order to make sure that the short-term setting is used only in the installation or
factory setting phase and not during daily use. Power up the control unit, make
sure that no other control units having an empty memory are powered up in the
same operating range.
Within 30 seconds after start, press the B and C buttons simultaneously until the
motor gives a confirmation signal.
T1: First remote control to be set
After the last confirmation movement, the motor starts a series of UP and DOWN
movements: the first lasts 2 seconds, the next ones go to the limit switch positions
(motors with mechanical limit switches) or long movements - max 10 seconds
(motors with electronic limit switches). To properly associate the UP and DOWN
buttons, press the button corresponding to the motor movement for one second
as indicated below:
?
The remote control will remain stored for 5 minutes, while the control unit is powered
up. After 5 minutes or when the control unit has its power cut off, the remote control
will be cancelled.
TM2 X R COMPACT
SPECIAL FUNCTIONS
+
B
C
T1
A
C
T1 (1 sec)
37
The motor stops: the
UP and DOWN buttons
are now properly
associated.
A4518_6H81_Rev.A