2-BUTTON SWITCH

It is possible to run the motor through a switch connected to the control unit with
three wires (up, down and common).
The switch must be equipped with mechanical or electrical interlock, to prevent
two commands being sent simultaneously. Furthermore, the switch must be an
unstable pushbutton: releasing it, the switch opens.
L
N
PE
E P
CONTROL UNIT
The motor automatically recognizes the switch-type (with 1 or 2 buttons) and sets the
proper operational mode.

COMMAND MANAGEMENT FROM WHITE WIRE

NB: The default function provided in the motors leaving the factory is: UP-STOP-
DOWN-STOP for singular UP/DOWN button switch. (Not for the switch with two
independent UP-DOWN buttons!)
+
B
C
The possible settings are 3 and are available in the following order:
- UP-STOP-DOWN-STOP (factory setting)
- UP-DOWN (for 2 independent buttons)
- UP-DOWN "Dead Man" (for 2 independent buttons)
To switch from one setting to the following, perform the sequence as many times
as necessary to reach the desired setting.
TM2 X R COMPACT
1 - NEUTRAL
2 - PHASE
3 - WIRED SWITCH (WHITE)
1
2 3
PE - EARTH
B