The battery pack can stay connected to the battery charger for an indefinite period of time, because
it is protected against overcharging.
NOTICE
When the battery pack is not in use, it is advised to keep it connected to the battery charger
(connected to a power source) at all times. When the battery pack is full, the battery charger
automatically switches on and off at regular intervals to keep the battery level at 100%.
After deep discharge of the battery pack, charge the battery pack for 24 hours. If the battery
pack is not completely charged after 24 hours, contact your local Holmatro dealer.
5.3
Installing the battery pack
Put the battery pack in the battery pack fitting / adapter fitting until the battery pack locks.
5.4
Connecting to an external power source
See Fig. 5.
Apart from using the battery pack, the tool can also be connected to the mains by the special mains
connector. Use only the original mains connector for this purpose.
Slide the adapter of the mains connector in the battery pack fitting / adapter fitting until the battery
pack lock snaps tight.
Insert the plug of the mains connector into the appropriate power outlet.
5.5

Starting the tool

Operate the on/off switch to activate the tool. The green LED will light and the electric motor runs at
slow speed.
The tool operates if the deadman's handle is turned to position
NOTICE
If the tool is not used, it will switch off after a while. The green LED will blink. Press the on/off
switch 2 times to re-activate the tool.
NOTICE
When the tool is not used for 10 minutes the battery pack will switch off. The green LED will
not light anymore. To activate the battery pack again:
Press the SOC indicator button, or
Operate the on/off switch again, or
Reinstall the battery pack.
5.6
Operate the deadman's handle
The deadman's handle is used to determine the movement of the plunger(s). In the neutral position no
pressure is built up and the oil flows back to the pump without pressure. If the deadman's handle is
released, it returns automatically to the neutral position and stops the movement of the plunger(s).
/i
Hold the deadman's handle in this position to open the tool/blades. Pressure is built
up in the tool. Return oil from the tool flows back to the pump without pressure.
Hold the deadman's handle in this position to close the tool/blades. Pressure is built
up in the tool. Return oil from the tool flows back to the pump without pressure.