Gap Sensor Manual-Calibration - Oki LD620D Guia Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 110

5-5 Gap Sensor Manual-Calibration

Manual-calibration of media detection can be used when the printer cannot detect a media
gap (or black mark) even after auto-calibration has been executed.
Users can calibrate sensor parameters in detail by using the utility program provided by the
manufacturer.
The utility can be obtained from the enclosed CD.
Please make sure the printer is connected and execute the utility program.
Please the Calibration Setting Manager Button after setting the interface type.
1) Select the sensing type and input the label length by millimeter and click on "Check
Sensing Value" tap. Then printer starts to calibrate.
2) Printer will print the scanned values after calibration and the values will appear on the
Screen.
3) Optimal sensing values will appear in black bold letters on the left of the utility screen and
select one of the values and click on "Save Calibration"
4) If chosen value does not work properly, please try the other values among the black bold
letters.
5) To go back to the initial value, please click on "Cancel Calibration"
Rev. 1.0
- 19 -
LD620D

Publicidad

Tabla de contenido
loading

Tabla de contenido